The paper presents the research results of field measurements campaign of natural ventilation performance and effectiveness in a residential building. The building is located in the microclimate whose parameters differ significantly in relation to a representative weather station. The measurement system recorded climate parameters and the physical variables characterizing the air flow in the rooms within 14 days of the winter season. The measurement results showed that in spite of proper design and construction of the ventilation system, unfavorable microclimatic conditions that differed from the predicted ones caused significant reduction in the efficiency of the ventilation system. Also, during some time periods, external climate conditions caused an opposite air flow direction in the vent inlets and outlets, leading to a significant deterioration of air quality and thermal comfort measured by CO2 concentration and PMV index in a residential area.
REFERENCES(29)
1.
Awbi H. “Ventilation of building”, E & FN Spon, 2003.
Burek R, Połednik B, Raczkowski A. “Study of the relationship between the perceived air quality and the specific enthalpy of air polluted by people”, Archiwum Ochrony Środowiska 2006.
Fountain M, Huizenga C, "A thermal sensation model for use by the engineering profession, Results of Cooperative Research Between ASHRAE and Environmental Analytics", ASHRAE RP-781 Final Report, Piedmont, 1995.
Kleiven T. "Natural Ventilation in Buildings. Architectural concepts, consequences and possibilities", Thesis submitted in partial fulfilment of the requirements for the degree of Doktor at Norwegian University of Science and Technology Faculty of Architecture and Fine Art Department of Architectural Design, History and Technology, 2003.
Lau J, Chen Q. “Energy analysis for workshops with floor-supply displacement ventilation under the U.S. climates”, Energy and Buildings 2006; 38: 1212-1219.
Mochida A, Yoshino H, Takeda T, Kakegawa T, Miyauchi S. “Methods for controlling airflow in and around a building under cross ventilation to improve indoor thermal comfort”, Journal of Wind Engineering and Industrial Aerodynamics 2005; 93: 437-449.
Ravikumar P, Prakash D, "Analysis of thermal comfort in a residential room with insect proof screen: A case study by numerical simulation methods", Building Simulation 4 (2011).
Tsutsumia H, Tanabea S, Harigayaa J, Iguchib Y, Nakamura G. “Effect of humidity on human comfort and productivity after step changes from warm and humid environment”, Building and Environment, 2006.
EN ISO 15927-4. Hygrothermal performance of buildings - Calculation and presentation of climatic data - Part 4 Data for assessing the annual energy for cooling and heating systems.
ISO 7730:2005, Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria, International Organization for Standarization, Geneva, 2005.
We process personal data collected when visiting the website. The function of obtaining information about users and their behavior is carried out by voluntarily entered information in forms and saving cookies in end devices. Data, including cookies, are used to provide services, improve the user experience and to analyze the traffic in accordance with the Privacy policy. Data are also collected and processed by Google Analytics tool (more).