ORIGINAL ARTICLE
Cod Fractions In Mechanical-Biological Wastewater Treatment Plant
 
More details
Hide details
1
University of Zielona Gora, Institute of Environmental Engineering, Szafrana st 15, 65-246 Zielona Góra, Poland
 
 
Online publication date: 2017-05-17
 
 
Publication date: 2017-03-28
 
 
Civil and Environmental Engineering Reports 2017;24(1):207-217
 
KEYWORDS
ABSTRACT
The paper presents results of studies concerning the designation of COD fraction in the raw, mechanically treated and biologically treated wastewater. The test object was a wastewater treatment plant with the output of over 20,000 PE. The results were compared with data received in the ASM models. During investigation following fractions of COD were determined: dissolved non-biodegradable SI, dissolved easily biodegradable SS, in organic suspension slowly degradable XS and in organic suspension non-biodegradable XI. Methodology for determining the COD fraction was based on the guidelines ATV-A 131. The real percentage of each fraction in total COD in raw wastewater are different from data received in ASM models.
 
REFERENCES (28)
1.
Brdjanovic D., Van Loosdrecht M.C.M., Versteeg P., Hooijmans Ch.M., Alaerts G.J., Heijnen J.J.: Modeling COD, N and P removal in a full-scale WWTP Haarlem Waarderpolder. Water Research 34, No 3, (2000), 846-858.
 
2.
Brun R., Kühni M., Siegrist H., Gujer W., Reichert P.: Practical identifiability of ASM2d parameters-systematic selection and tuning of parameter subsets. Water Research 36, (2002),113-4127.
 
3.
Dulekgurgen E., Dogruel S., Karahan O., Orhon D.: Size distribution of wastewater COD fractions as an index for biodegradability. Water Research 40, (2006),273-282.
 
4.
Ekama G.A., Dold P.,L., Marais G.v.R.: Procedures for determining influent COD. Fractions and the maximum species growth rate of heterotrophs in activated sludge systems. Wat.Sci.Tech. No.18, (1986),94-114.
 
5.
Gernaey K.V., Van Loosdrecht M.C.M., Henze M., Lind M.,Jorgensen S.B.: Activated sludge wastewater treatment plant modelling and simulation: state of art. Environmental Modelling&Software 19, (2004), 763-783.
 
6.
Gujer W., Henze M., Mino T., Matsuo T., Wentzel M.C., Marais G.v.R.: The activated sludge model no.2: Biological phosphorus removal, Wat. Sci. Tech. Vol.31, No.2, (1995),1-11.
 
7.
Gujer W., Henze M., Mino T., Van Loosdrecht M.: Activated sludge model No.3. (1999), Pergamon.
 
8.
Henze M., Grujer W., Mino T., Matsuo T., Wentzel M.C., Marais Gv.R., Van Loosdrecht M.C.M.: Activated Sludge Model No.2D ASM2D. Pergamon, Water Science and Technology 39, No.1, (1999),165-182.
 
9.
Henze M., Gujer W., Mino T., Matsuo T., Wentzel M.C., Marais G.v.R.: Wastewater and biomass characterization for the activated sludge model no.2: Biological phosphorus removal, Wat. Sci. Tech. Vol.31,No.2, (1995),13-23.
 
10.
Henze M., Gujer W., Mino T., Van Loosdrecht M.: Activated sludge models ASM1, ASM2, ASM2d, ASM3. Iwa Task Group On Mathematical Modelling For Design And Operation Of Biological Wastewater Treatment, London 2007.
 
11.
Hu Z., Chandran K., Smets B.F., Grasso D.: Evaluation of rapid physicalchemical method for the determination of extant soluble COD. Water Research 36, (2002), 617-624.
 
12.
Karahan ö., Dogruel S., Dulekgurgen E., Ohron D.: COD fraction of tannery wastewaters-Particle size distribution, biodegradability and modeling. Water Research 42, (2008), 1083-1092.
 
13.
Lagarde F., Tusseau-Vuillemin M-H., Lessard P., Héduit A., Dutrop F., Mouchel J-M.: Variability estimation of urban wastewater biodegradable fractions by respirometry. Water Research 39, (2005), 4768-4778.
 
14.
Mąkinia J. Wells S.A.: A general model of the activated sludge reactor with dispersive flow-I.model development and parameter estimation. Water Research Vol.34, No.16. (2000) 3987-3996.
 
15.
Melcer H., Dold P.L., Jones R.M., Bye Ch.M., Takacs I., Stensel H.D., Wilson A.W., Sun P., Bury S.: Treatment Processes and Systems. Methods for Wastewater Characterization in Activated Sludge Modeling. Water Environment Research Foundation, 2003.
 
16.
Melcer H., Dold P.L., Jones R.M., Bye Ch.M., Takacs I., Stensel H.D., Wilson A.W., Sun P., Bury S.: Treatment Processes and Systems. Methods for Wastewater Characterization in Activated Sludge Modeling, Water Environment Research Foundation 2003.
 
17.
Myszograj S.: Charakterystyka frakcji ChZT w procesach mechanicznobiologicznego oczyszczania ścieków. II Kongres Inżynierii Środowiska, Monografie Komitetu Inżynierii Środowiska PAN, 39 (2005), Lublin.
 
18.
Nopens I., Badstone D.J., Copp J. B., Jeppson U., Volcke E., Alex, Vanrollehghem P.A.: An ASM/ADM model interface for dynamic plant-wide simulation. Water Research 43, (2009),1913-1923.
 
19.
Orhon D., Ates E., Sözen S., Cokgör E.U.: Characterization and Cod fractionation of domestic wastewaters. Environmental Pollution, vol.95, no.2. (1997), 191-204.
 
20.
Pasztor I., Thury P., Pulai J.: Chemical oxygen demand fractions of municipal wastewater for modeling of wastewater treatment. International Journal of Environmental Science and Technology, Vol.6,No.1, (2009),51-56.
 
21.
Petersen B., Gernaey K., Henze M., Vanrolleghem P.A.: Calibration of activated sludge models: A critical review of experimental designs Biotechnology for the environment: soil remediation. Red. S.N. Agathos, W. Reineke. Kluwer Academic Publishers, Dordrecht 2002.
 
22.
Płuciennik-Koropczuk E.: Frakcje ChZT miarą skuteczności oczyszczania ścieków. Gaz, Woda i Technika Sanitarna nr 7-8, (2009), 11-13.
 
23.
Sadecka Z., Myszograj S.: Frakcje ChZT w procesach mechanicznobiologicznego oczyszczania ścieków na przykładzie oczyszczalni ścieków w Sulechowie. Rocznik Ochrona Środowiska T. 6, (2004), 233-244.
 
24.
Sadecka Z., Płuciennik-Koropczuk E.: Frakcje ChZT ścieków w mechaniczno-biologicznej oczyszczalni. Rocznik Ochrona Środowiska -, T. 13 cz.2, (2011), 1157-1172.
 
25.
Spérandio M., Etienne P.: Estimation of wastewater biodegradable COD fractions by combining respirometric experiments in various SO/XO ratios. Water Research 34.No.4, (2000),1233-1246.
 
26.
Vandekerekhove A., Moerman W., Van Hulle S.W.H.: Full-scale modeling of a food industry wastewater treatment plant in view of process upgrade, Chemical Engineering Journal 135, (2008), 185-194.
 
27.
Vanrolleghem P.A., Spanjers H., Petersen B., Ginestet P., Takacs I.: Estimating Combination of activated sludge model no.1 parameters and components by respirometry, Wat. Sci.Tech., (1999), 195-214.
 
28.
Wytyczna ATV - DVWK - A 131 P., Wymiarowanie jednostopniowych oczyszczalni ścieków z osadem czynnym. Wydawnictwo Seidel - Przywecki, 2002.
 
eISSN:2450-8594
ISSN:2080-5187
Journals System - logo